Level 1 sweep and inspection to the NFPA 211 annual standard - flue, crown, cap, and flashing checked and photographed
Chimney sweep logs do not sweep chimneys. They loosen some creosote - which then falls where a brush and vacuum still have to collect it.
Gelco Flue Liner Replacement: The Clifton Owner’s Guide
Gelco flue liner replacement in Clifton typically runs $2,900 to $4,800 installed, depending on the liner diameter, height of your flue, and whether we’re doing a straight swap or pulling corroded sections that have fused to the masonry. We stock direct-fit Gelco stainless liners on the truck, and most Clifton jobs are finished in one day. The way homeowners usually discover the liner has failed isn’t dramatic. It’s a sweep that finds rust flaking onto the smoke shelf, or water staining on the ceiling near the chimney chase, or a gas odor that comes and goes with the weather. By the time you’re searching for a replacement part, the liner has usually been quietly deteriorating for a couple of seasons.
Here’s what you’re dealing with: a Gelco liner is a stainless steel tube that runs the full height of your chimney. When it was installed, it was sized to your specific appliance, whether that’s a furnace, boiler, or water heater. When it fails, the fix isn’t a patch. It’s a measured removal and a new liner dropped and connected. We do this work in Clifton regularly, and we’ll walk through exactly what it costs before we touch a tool.
Key takeaways:
- Installed Gelco liner replacement in Clifton: $2,900 to $4,800 range, written quote before work starts
- We stock Gelco-compatible stainless liners in common diameters; odd sizes are sourced within 48 hours
- Most replacements finish in one day, including camera documentation after the install
- You’ll get a written price, written scope, and written warranty before anyone starts, per Haven Standard Clause 1
- Haven Standard Clause 4 means a camera-scan photo record is included on every job, not an add-on
Which Gelco Models This Applies To
Gelco is a manufacturer of flexible stainless steel liners, not appliances, so your liner’s compatibility comes down to three measurements: diameter, length, and whether it’s smooth-wall or corrugated. The liner is sized to the BTU output of your appliance and the interior dimensions of your existing flue. Common Gelco diameters we replace in Clifton are 4″, 5″, 6″, and 7″, with the smaller sizes typically tied to water heaters and the larger to furnaces and boilers. The length is determined by your chimney’s height from appliance collar to crown.
How to identify your current liner before you call: look for the Gelco label or etching near the appliance connection, usually on a metal tag attached at the base or along the first few feet of flex. If the tag is gone, which happens often after a decade of heat cycling, we can measure the inner diameter on site. One of the compatibility gotchas with Gelco specifically: the brand uses a corrugated profile that’s slightly deeper than some aftermarket equivalents, meaning the inner diameter can read smaller than nominal. We carry a caliper and measure for real, because guessing here leads to a liner that either doesn’t draft or doesn’t seal. For gel-fueled or pellet applications, the spec matters even more, clearance to combustibles is tighter.
On the OEM-versus-aftermarket question: Gelco no longer sells direct to homeowners, and its product line has been consolidated. A quality aftermarket liner made from 316Ti alloy, which is what we source, equals or exceeds original Gelco specs for corrosion resistance and temperature rating. Level Two Chimney Clifton is an independent service provider, not affiliated with Gelco. We also stock and install liners from DuraFlex and HeatShield, and we’ll match by measurement and application, not by brand loyalty. If your appliance needs a specific liner kit with a tee and cap, we’ll tell you what the part number should look like and what a reasonable price is for it.
Signs Your Gelco Flue Liner Replacement Is Failing

- Rust flakes in the cleanout or at the smoke shelf. The liner is corroding from the inside, usually from condensation created when acidic exhaust gases hit a cold liner. In Clifton, where winters run long and damp, we see this more than in drier climates.
- Water staining on the ceiling or walls near the chimney chase, especially after a hard rain. The liner has pitted through or the crown is failing, letting water into the surrounding structure.
- A gas smell in the house when the furnace or boiler kicks on, but faint and intermittent. Exhaust that should be going up is leaking through a breach in the liner. This is a carbon monoxide risk and should be addressed immediately, no waiting for the next sweep.
- White crust or scaling on the exterior brick, often near the top third of the chimney. Moisture is moving through the masonry because the flue liner is compromised and condensation is soaking into the brick.
- Unexplained draft odors, soot streaks, or back-puffing when the appliance starts. The liner may have separated at a joint, slumped, or collapsed in a section. Older Gelco liners can develop tears at the seam welds, particularly if they were installed with an aggressive pull angle.
None of these symptoms gets better on its own. The liner is sealed from the outside. When the wall’s breached, the only repair is replacement.
Before
AfterReplacement Cost & What’s Included
Here’s the Clifton price picture, in dollars, not “call for a quote.”
| Item | Typical cost |
|---|---|
| Gelco-compatible stainless liner, 5″ x 25′, including connectors | $680 to $980 |
| Labor: removal, drop, connection, sealing, and testing | $1,600 to $2,600 |
| Crown repair or new rain cap, if needed | $220 to $600 |
| Camera inspection and photo documentation | Included under Haven Standard Clause 4 |
| Full installed range, typical Clifton home | $2,900 to $4,800 |
The spread comes from three things: flue height, access, and the condition of what surrounds the liner. A two-story house in the Dutch Hill or Athenia sections with a steep roof pitch costs more than a single-story ranch near Main Memorial Park. If the existing liner was installed poorly, sometimes it comes out in pieces and each fragment has to be pulled individually. We don’t charge extra for that frustration. The written quote you get before we start is the price you pay, unless we find something structural that changes the scope, and then we stop and re-scope in writing before continuing.
Every Gelco liner replacement in Clifton comes with our 365-Day Done Right Promise. If it’s not done right, we make it right. The warranty on the liner itself runs 10 years on material from our suppliers. The workmanship warranty is written on the invoice. The camera footage after the install is included, and it shows the full liner from appliance connection to crown cap. You see what we saw before and after, because Clause 4 of the Haven Standard requires a photo record on every job. It’s been that way since 2009, and it means you never have to wonder if a new liner was actually dropped or if we just buffed the old one and called it good.
DIY or Call Us?

There’s a version of this job that’s honest DIY, and a version that’s not. You can safely pull the cleanout door and look for rust flakes. You can shine a flashlight up the flue from below if the appliance is cool. You can check for water staining around the chase. Those are inspection steps, and they’re useful. The camera doesn’t guess. Neither do we.
What you shouldn’t do is pull a liner yourself. Flexible stainless liners are under tension when installed, and the process of removal and re-drop requires two people on a roof, proper rigging, and knowledge of clearance to combustibles at the connection points. A torn liner can dump exhaust gas into an enclosed chase, and a liner that’s under-spec or poorly connected is a carbon monoxide risk that a visual check from the ground won’t catch. This is not a spring or tension part in the mechanical sense, but the safety stakes are in the same class. Leave the removal to a crew that does it weekly in Clifton, not once ever. If you’ve been quoted a price by someone else, bring it to us. A free second opinion on any written estimate is always available. Call (551) 282-9640 and we’ll put the camera down the flue and show you what we’re working with.
FAQs
A properly installed Gelco liner in the Clifton area typically lasts 15 to 20 years. The region’s damp, cold winters accelerate condensation, which shortens liner life compared to drier climates. Annual sweeping and keeping the crown sealed extend it. We see Clifton liners from the early 2000s failing now, which fits that timeline. Call (551) 282-9640 if you’re near the 15-year mark and want a camera check.
A Gelco liner with a small section of surface rust can sometimes be stabilized with a relining treatment like HeatShield, but any breach, tear, or seam separation is a replacement. Liners don’t patch. Welding a flex liner has never worked reliably because the weld is never as flexible as the surrounding corrugation and it becomes the next failure point. A camera scan will show you if a repair is actually possible or if you’re better off spending the replacement money once. Estimates are free at (551) 282-9640.
Most Gelco flue liner replacements in Clifton are done in one day, usually six to eight hours from start to finish. Odd sizes that we don’t stock on the truck run 48 hours for sourcing. The job includes removal, drop, connection, sealing, testing with the appliance running, and the camera-scan photo record.
We stock Gelco-compatible stainless liners in 4″, 5″, 6″, and 7″ diameters, in standard 25′ and 35′ lengths, on the truck. We also carry DuraFlex and HeatShield product. If your chimney needs a custom diameter or length, we source it within two business days.
Written by Corrine Halstead, Owner, Level Two Chimney Clifton at Level Two Chimney Clifton, serving Clifton and nearby areas.





Before
After
Before
After